IceCap
IceCap Reverse Osmosis Membrane Upgrade Kit
IceCap Reverse Osmosis Membrane Upgrade Kit
IceCap Reverse Osmosis Upgrade Kits will increase the production of any 75 GPD reverse osmosis system to 150 GPD or 100 GPD RO membrane up to 200 GPD while cutting the amount of wastewater nearly in half. With the installation of this kit, water production will increase from approximately three gallons per hour to six gallons per hour! The kit does require 65psi or more into the first membrane in order to function properly and be efficient.
Compatible with:
150 GPD Upgrade Kit- Most 75 GPD RO Systems
200 GPD Upgrade Kit- Most 100 GPD RO Systems
Recommended Conditions:
- Minimum Water Pressure - 65 PSI
- Max Water Pressure - 90 PSI
- Recommended Water Temperature - 77°F
- Recommended Max TDS - <300ppm
Recommended Flow Restrictor for 75 GPD RO Systems - 550mL/min
Recommended Flow Restrictor for 100 GPD RO Systems - 800mL/min
Upgrade Kit Includes:
- Dow RO Membrane
- 2 x 2.5in x 2.5in membrane stand-off clips
- 2 x 1/8" x ¼" 90-degree elbows (installed)
- 1/8" x ¼" 90° check valve (installed)
- RO membrane housing
- ¼" tube splitter
- 5 Feet of White RO Line
Not Included But Recommended:
Multiple DI canisters for 150 GPD/200GPD systems*
DOW Filmtec 75 GPD Membranes have a 96% - 99% typical stabilized salt rejection rate that can be reproduced through the following conditions;
- Source Water Pressure - 50 PSI / Membrane
- Source Water Temperature - 77°F
- Source Water TDS - 250ppm Softened Tap Water
- Recovery - 15%
- Minimum Salt Rejection - 96%
DOW Filmtec 100 GPD Membranes have a 96% - 98% typical stabilized salt rejection rate that can be reproduced through the following conditions;
- Source Water Pressure - 50 PSI / Membrane
- Source Water Temperature - 77°F
- Source Water TDS - 500ppm Softened Tap Water
- Recovery - 15%
- Minimum Salt Rejection - 96%
*High TDS Message - Source water with high total dissolved solids (TDS) we do not recommend using the membrane upgrade kit. If used you may experience increased DI consumption. The RO system with the upgrade kit will increase the water filtered and decreasing the amount of wastewater, but the overall amount of TDS passing the membranes may be slightly higher than a single membrane system. Because of that, your DI consumption will increase. It is suggested to use multiple DI canisters for 150 GPD/200GPD systems.
WARRANTY
CoralVue, Inc. and IceCap hereby guarantee this product to be free from defects in material and workmanship for a period of:
- 90 Days
Warranty is activated on the date of purchase.
This Standard Limited Warranty applies and is limited as follows:
- To the product only as long as it remains in the possession of the original purchaser.
- To the product that has not been subject to accident, misuse or abuse.
- To the product that has not been modified, altered, defaced, or had repairs made or attempted by other than CoralVue, Inc.
- That CoralVue be immediately notified in writing within ten (10) days of first knowledge of defect by owner or his agent.
- That CoralVue, Inc. shall be given first opportunity to make any repairs, replacements or corrections to the defective construction within a reasonable period of time.
- Under no circumstances shall CoralVue and/or the Manufacturer be liable by virtue of this warranty or otherwise for damage to any person or property whatsoever for any special, indirect, secondary or consequential damages of any nature however arising out of the use or inability to use because of the product defect.